Å·ÃÀÈÕb´óƬ

Skip to Main Navigation

Slovak Republic

Bratislava

image

Data Table with caption

Building Energy Code (BEC) currently in-force Act On The Energy Performance Of Buildings (no. 555/2005)
Date of BEC publication 2005
BEC Jurisdiction National
Climate zone classification Mixed, Humid
Income Group High income
Type of BEC Combination (Prescriptive/Performance-Based )
BEC Coverage Passive design; Space Heating; Space Cooling*; Water Heating*; Lighting*
* denotes coverage is through the European Ecodesign Directive

Indicator Mandatory Minimum Requirements
Maximum Solar Heat Gain Coefficient (SHGC) Yes
Roof U-value (W/m?. K) 0.15
Floors U-value (W/m?. K) 0.2
External walls U-value (W/m?. K) 0.22
Doors U-value (W/m?. K) 0.85
Air leakage prevention ..
Enforcement Mechanisms Checklist of Passive Design; Thermal Transmittance or Insulation Calculations for Building Envelope; Solar Heat Gains Calculations for Building Envelope; Glazing Factors for Fenestration; Permanent Shading; Air Barrier, Air Leakage, or Air Infiltration